Radiation Portal Monitoring
MyRPM

MyRPM is a Radiation Portal Monitoring System developed by Malaysian Company. Passive radiation detection devices is used for the screening of individuals, vehicles, cargo or other vectors for detection of illicit sources such as at borders or secure facilities.

Hardware Specification

SpecificationDescription
Dimension2 pillar per lane, each dimension:
Height: 3663 mm
Width: 1040 mm
Depth: 750 mm
including steel structure
CompliancePerformance - ANSI 42.35
Data Protocol - ANSI 42.42
Data OutputProvide alarm classification, alarm status, gamma count rates, neutron count rates and background count rates directly to third party user interfaces
Gamma Detector25.4 litre (38.5 x 122.3 x 5.4) cm plastic scintillator (PVTs) with integrated multichannel analyzer (MCA). The detector provide gamma radiation sensitivity in the energy range from 20keV to about 3 MeV, ensuring static efficiency and dynamic sensitivity in the whole detection range
Gamma SensitivityApprox. 150000 cps or µSv/h for Cs-137
Neutron Detectors87.2 litre (12.7 x 31.8 x 215.9) cm replace non He-3 material with 6LiF/ZnS(Ag) material. The entire assembly is enclosed within high density polyethylene moderator box
Neutron SensitivityMin. 2.5 cps/ng of moderated Cf-252 at 2 meters
Alarm CategorizationAlarm categorization allows optimal threat detection and minimal false alarm rate
PeripheralsOccuancy sensors; optional: CCTV, OCR, LPR, audible/visual alarm annunciation
Operation Temperature-30C - 55C (down to -40C optional)
Humidityup to 99%
Ingress ProtectionIP56 (other IP levels possible)
radiation portal monitor

Features

Models

MyRPM G2

Gamma Detectors : 2
1 Gamma Detectors on each side
Not have a Neutron Detector
Suitable for Civilian monitoring with a passenger vehicle
Suggested Installations :
  • Pedestrian Scanning
  • Hospitals (Nuclear Medicine Departments)
  • Airports
  • Schools & University Labs

MyRPM G4

Gamma Detectors : 4
2 Gamma Detectors on each side
Not have a Neutron Detector
Suitable for Institutions / Agencies that use Heavy Vehicles
Suggested Installations :
  • Radionuclide Production Labs
  • Facilities for the Radiation Industry
  • Nuclear Research Facilities

MyRPM G2N2

Gamma Detectors : 2
Neutron detectors : 2
1 Gamma Detector &
1 Neutron Detector
on each side
Includes Neutron Detectors
Suitable for Places that transport goods to prevent illegal trafficking of radiation sources.
Suggested Installations :
  • Seaports
  • Scrapyards

MyRPM G4N2

Gamma Detectors : 4
Neutron detectors : 2
2 Gamma Detector &
1 Neutron Detector
on each side
Includes Neutron Detectors
Suitable for Places that use Heavy Vehicles to transport minerals. 
Suggested Installations :
  • Rare Earth Ming Site

Features In Each Model

SpecificationMyRPM G2MyRPM G4MyRPM G2N2MYRPM G2N4
Gamma DetectorYes (One Each Side)Yes (Two Each Side)Yes (One Each Side)Yes (Two Each Side)
Neutron DetectorNoNoYes (One Each Side)Yes (One Each Side)
Desktop SoftwareYesYesYesYes
Mobile ApplicationYes (with Addon)Yes (with Addon)Yes (with Addon)Yes (with Addon)

Addons

Mobile Connection & Wireless System
Solar Energy & Battery Backup System
Server & Cloud Data Storage